Built to order

DIY Digital TDS Meter with Water Quality Display using Arduino

This project builds a DIY digital TDS meter using an Arduino Uno, an analog TDS probe and a 16x2 LCD that shows total dissolved solids in water as a ppm reading on a local display. The probe measures the water's electrical conductivity, the Arduino converts it to ppm with temperature compensation from a DS18B20 sensor, and the reading appears on the LCD seconds after dipping the probe. It is a standalone handheld meter with no cloud or app, for checking tap, RO and borewell water. Suitable for B.E./B.Tech final-year projects in Electronics, E&TC and Electrical Engineering.

Chat on WhatsApp — get a quotation

Electronics / E&TC Arduino Uno R316x2 LCD displayDS18B20 temperature sensorArduino IDE · C++ firmwareBreadboard jumper wires9 V battery USB powerSerial Monitor loggingGravity analog TDS sensor SEN0244Hardware
DIY Digital TDS Meter with Water Quality Display using Arduino — project thumbnail preview
More project photos (2)

The problem

A DIY digital TDS meter with water quality display using Arduino is a handheld instrument that measures total dissolved solids in a water sample and shows the result in parts per million (ppm) on a 16x2 LCD. This project builds that meter around an Arduino Uno, a Gravity analog TDS probe and a DS18B20 temperature sensor: the probe measures how well the water conducts electricity, the Arduino converts that conductivity into a ppm value, corrects it for temperature, and prints the reading on the display. A TDS meter does not weigh the dissolved solids directly. It measures electrical conductivity, because dissolved salts and minerals carry current, and multiplies the conductivity by a conversion factor — 0.5 for a sodium-chloride reference in this build — to estimate the ppm value. That estimate is useful for comparing tap, RO and borewell water and for checking whether a filter is still doing its job, but it is an estimate, not a laboratory measurement.

Method What you get Result time Needs a lab
DIY digital TDS meter (this project) Conductivity-derived ppm on an LCD Seconds No
Test strips Colour-match band, single use Minutes No
Laboratory gravimetric analysis Weighed dissolved solids Days Yes

Most households and hostels judge water quality by taste, colour or trust in the filter, and none of those tells you whether dissolved solids are rising as a filter ages. A lab test gives a precise number but takes days and a visit, while colour-change test strips give only a rough band and are used once and thrown away. This project fills the gap between the two: a reusable meter a student can build, calibrate and explain, that gives a repeatable ppm reading in seconds at the tap. It is deliberately a standalone meter, not a cloud monitor, so the learning stays on the sensing chain — probe, conversion, compensation and display — rather than on networking.

SYSTEM FLOW

4 components 3 connections

Live flow
Drag to explore
100%
sensorTDS Probe

Dipped in the sample; the water's conductivity rises with dissolved solids.

Follow the working sequence

How it works

The meter works as a short sensing chain: probe, voltage, conversion, compensation and display. The TDS probe sits in the water sample and the Gravity signal board drives it with an alternating-current excitation signal, which avoids electrode polarisation and keeps the output stable over repeated dips. The board outputs an analog voltage between 0 and 2.3 V that rises with the water's conductivity, and the Arduino Uno reads that voltage on an analog pin with its 10-bit ADC, giving a value from 0 to 1023. Firmware converts the voltage to electrical conductivity, applies the temperature correction from the DS18B20 reading to a 25 °C reference, and multiplies by the 0.5 conversion factor to produce the ppm value. The result is averaged over consecutive samples, then printed on the 16x2 LCD beside the temperature, and the whole cycle repeats every couple of seconds so the display tracks the water as it settles.

  1. Rinse the probe in clean water, then dip it into the sample so the electrodes are fully covered and the probe is clear of the container walls.
  2. Power the Arduino from USB or a 9 V battery; the LCD lights and shows the startup screen.
  3. The Gravity signal board excites the probe with an AC signal and outputs 0–2.3 V in proportion to the water's conductivity.
  4. The Uno reads that voltage on analog pin A0 with its 10-bit ADC and reads the water temperature from the DS18B20 sensor.
  5. Firmware converts the voltage to conductivity, corrects it to the 25 °C reference using approximately 2% per °C, and multiplies by the 0.5 conversion factor to get the ppm value.
  6. The firmware averages 10 consecutive samples and prints the ppm value, the temperature and the quality band on the 16x2 LCD.
  7. Lift the probe out, rinse it in clean water and shake off the droplets before the next sample, so residue from one sample does not carry into the next reading.

Builder note from the demo build: a reading that will not settle is usually residue from the previous sample, not a faulty sensor — rinse the probe in clean water and shake off the droplets before each new sample.

Tech stack:

  • Arduino Uno R3 (ATmega328P)
  • Gravity analog TDS sensor · SEN0244
  • DS18B20 temperature sensor
  • 16x2 LCD display
  • Arduino IDE · C++ firmware
  • Breadboard · jumper wires
  • USB power · 9 V battery
  • Serial Monitor logging
Parameter Value
Controller Arduino Uno R3 · ATmega328P at 16 MHz (datasheet)
TDS sensor Gravity analog TDS sensor · SEN0244 (datasheet)
TDS measurement range 0–1000 ppm (datasheet)
Sensor output 0–2.3 V analog (datasheet)
Sensor supply 3.3–5.5 V (datasheet)
Sensor current 3–6 mA (datasheet)
Sensor accuracy ±10% F.S. at 25 °C (datasheet)
Temperature sensor DS18B20 · ±0.5 °C from −10 °C to +85 °C (datasheet)
ADC resolution 10-bit · 0–1023 (Arduino datasheet)
Conversion factor 0.5 · NaCl reference (design target · configurable in code)
Temperature coefficient Approximately 2% per °C (design target)
Display 16x2 character LCD
Power USB 5 V or 7–12 V recommended via barrel jack (datasheet)
Probe limit Not for water above 55 °C (datasheet)
Reading update Approximately every 2 seconds (design target)

Project features

The meter's four strongest capabilities are its direct ppm readout, its temperature-compensated conversion, its buyer-run calibration procedure and its fully standalone operation. The 16x2 LCD shows the TDS value in ppm beside the water temperature, so a reading is visible the moment the probe settles, with no phone, app or computer needed. A DS18B20 temperature sensor feeds the compensation step, because conductivity rises by approximately 2% per degree Celsius, and without that correction the same water reads differently on a hot afternoon and a cold morning. Calibration is a documented one-point procedure against a standard reference solution, so the student can set the meter against a known value and repeat the check before a demonstration. Everything runs on the Arduino Uno from USB or a 9 V battery, which makes the meter genuinely portable for testing water at different taps, and the serial output mirrors every reading for logging and debugging.

  • [Direct ppm readout on 16x2 LCD] The TDS value in ppm and the water temperature appear on the LCD seconds after the probe is dipped, with no phone, app or computer needed to see the result.
  • [Temperature-compensated conversion] A DS18B20 sensor measures the water temperature and the firmware corrects the conductivity to a 25 °C reference, so the same water reads consistently across hot and cold samples.
  • [One-point calibration procedure] The meter is calibrated against a standard reference solution of known ppm by adjusting a single constant in the firmware, and the documented procedure can be repeated before any demonstration.
  • [Averaged, settled readings] The firmware averages 10 consecutive analog samples before updating the display (design choice), so the reading settles instead of flickering with every small fluctuation.
  • [Water-quality band on the display] The LCD shows a simple Low, Moderate or High band beside the ppm value, based on thresholds set in the code that can be changed for the water being tested.
  • [Standalone handheld operation] The meter runs from USB power or a 9 V battery with no internet, Wi-Fi or app, so it can be carried to different taps and used on the spot.
  • [Serial logging output] Every reading is mirrored to the Arduino Serial Monitor, which makes debugging straightforward and lets the student record readings during testing.

What is included

  • Working Arduino + TDS probe + LCD prototype, wired and tested
  • Complete firmware (Arduino IDE sketch) with calibration and temperature-compensation code
  • Wiring diagram and component list
  • Buyer-run calibration procedure against a standard reference solution
  • Project report PDF (background, TDS theory, circuit, methodology, results)
  • PPT presentation for final review
  • Viva Q&A preparation document (conductivity, conversion factor, temperature compensation, calibration)
  • Project abstract PDF

Timeline

  • Typical build timeline: approximately 2–3 weeks from order confirmation, including component sourcing, assembly, calibration and documentation.

Support

  • Support includes setup guidance over WhatsApp, help with the calibration procedure, and corrections to the report and PPT for college-format requirements.

Limitations & prerequisites

  • The ppm value is an estimate derived from conductivity, not a weighed laboratory measurement; different dissolved salts conduct differently, so the same ppm can read differently across water sources.
  • Datasheet accuracy is ±10% of full scale at 25 °C, so readings are indicative rather than laboratory grade.
  • The 0.5 conversion factor suits a sodium-chloride reference; mixed natural waters are often closer to 0.64, so the factor must be chosen for the water being tested.
  • The sensor range is 0–1000 ppm (datasheet); water above that range saturates the reading, and seawater is far outside it.
  • The probe must not be used in water above 55 °C (datasheet), and the signal board and connectors are not waterproof — only the probe may be immersed.
  • The meter measures dissolved solids only; it does not measure pH, turbidity, hardness or bacterial contamination, and it is an academic prototype, not a certified water-testing instrument.

Frequently Asked Questions

Is this project suitable for a final-year project?

Yes — it suits Electronics, E&TC and Electrical final-year projects because it combines analog sensor interfacing, ADC conversion, temperature compensation and calibration in one compact build, and the report explains the conductivity-to-ppm conversion and the temperature correction so the student can defend the measurement chain in the viva.

How accurate is the TDS reading?

The sensor datasheet states ±10% of full scale at 25 °C, so the meter is indicative rather than laboratory grade. Accuracy also depends on the calibration step and on which salts dominate the water, because the conversion factor is an empirical value, not a universal constant. It is reliable for comparing samples and tracking changes, not for certifying drinking water.

How do I calibrate the meter?

Calibration is a buyer-run one-point procedure. Rinse the probe, dip it into a standard calibration solution of known ppm, wait for the reading to settle, then adjust the calibration constant in the firmware until the display matches the solution value. The procedure is documented step by step, and the check should be repeated before a demonstration.

Which water can it test?

Tap water, RO water, borewell water and stored drinking water all fall inside the 0–1000 ppm range the sensor covers, while water above 1000 ppm saturates the reading and seawater is far beyond the range, and hot water above 55 °C must not be tested because the probe is not rated for it.

Does it need internet, Wi-Fi or an app?

No — the meter is fully standalone: the reading appears on the 16x2 LCD and the Arduino needs only USB or battery power, with no cloud upload, no app and no Wi-Fi, so readings are not stored or shared anywhere at all. A computer is needed only to upload the firmware and to view serial logs.

Can pH, turbidity or cloud logging be added later?

Yes, as optional customisation on request. A pH probe or a turbidity sensor can be added on spare analog pins with a second LCD line, and an ESP32 swap or a Bluetooth module can add logging or a phone display. These are not part of the base build and are quoted separately, because they change the wiring, the code and the calibration procedure.

Get this project: message Projectech on WhatsApp for a quotation — share your branch, the scope you need and your submission deadline, and the build is prepared to order with the prototype, firmware and documentation.

Components & software requirements
  • Arduino Uno R3 (ATmega328P)
  • Gravity analog TDS sensor · SEN0244
  • DS18B20 temperature sensor
  • 16x2 LCD display
  • Arduino IDE · C++ firmware
  • Breadboard · jumper wires
  • USB power · 9 V battery
  • Serial Monitor logging
Delivery information

Built-to-order project. Delivery timeline is shared after order confirmation based on current queue.

Support terms

Complete documentation, setup guide, and viva preparation included. Support for setup and explanation provided.

Download free synopsis (PDF)

Enter your name and WhatsApp number — the synopsis PDF downloads immediately. We may send occasional project updates on WhatsApp; no spam.

Get a quotation